Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Sci Rep ; 11(1): 20549, 2021 10 15.
Article in English | MEDLINE | ID: covidwho-1500755

ABSTRACT

Dried blood samples (DBSs) have many advantages; yet, impediments have limited the clinical utilization of DBSs. We developed a novel volumetric sampling device that collects a precise volume of blood, which overcomes the heterogeneity and hematocrit issues commonly encountered in a traditional DBS card collection as well as allowing for more efficient extraction and processing procedures and thus, more efficient quantitation, by using the entire sample. We also provided a thorough procedure validation using this volumetric DBS collection device with an established quantitative proteomics analysis method, and then analyzed 1000 proteins using this approach in DBSs concomitantly with serum for future consideration of utility in clinical applications. Our data provide a first step in the establishment of a DBS database for the broad application of this sample type for widespread use in clinical proteomic and other analyses applications.


Subject(s)
Dried Blood Spot Testing/instrumentation , Microarray Analysis , Proteomics/instrumentation , Adult , Aged , Female , Humans , Immunoassay , Male , Middle Aged
2.
Diagn Microbiol Infect Dis ; 101(1): 115425, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1230427

ABSTRACT

The COVID-19 pandemic led to development of numerous serologic tests. To obviate the need for phlebotomy services, we validated dried blood spots (DBS) for anti-SARS-CoV-2 serologic testing. Immunoglobulins were extracted from 3 mm DBS punches and the extracts were analyzed using the Euroimmun anti-SARS-CoV-2 IgG ELISA. Various pre-analytical factors were studied. Results were favorable for DBS stored for at least 67 days at or below 37°C. Comparison between paired serum and DBS specimens tested by the Euroimmun ELISA showed 96.8% and 81.3% positive and negative agreement, respectively, indicating that confirmatory testing of positive Euroimmun results on DBS extracts is necessary to achieve clinical accuracy. Our findings suggest that any SARS-CoV-2 antibody assay that requires pre-dilution of serum is amenable to DBS as an alternate specimen type that is relatively low cost, self-collectable, stable, can be shipped by standard mail and could be used to establish the seroprevalence of large populations.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing , COVID-19/diagnosis , Dried Blood Spot Testing , Immunoglobulin G/blood , SARS-CoV-2/isolation & purification , COVID-19 Serological Testing/instrumentation , Dried Blood Spot Testing/instrumentation , Enzyme-Linked Immunosorbent Assay , Humans , SARS-CoV-2/immunology , Sensitivity and Specificity , Specimen Handling
3.
Sex Transm Infect ; 97(3): 209-214, 2021 05.
Article in English | MEDLINE | ID: covidwho-1189914

ABSTRACT

OBJECTIVES: We comparatively evaluated two HIV and syphilis blood sampling kits (dried blood spot (DBS) and mini tube (MT)) as part of an online STI postal sampling service that included tests for chlamydia and gonorrhoea. We aimed to see how the blood collection systems compared regarding sample return rates and result rates. Additionally, we aimed to observe differences in false-positive results and describe a request-to-result ratio (RRR)-the required number of kit requests needed to obtain one successful result. METHODS: We reviewed data from an online postal STI kit requesting service for a client transitioning from MT to DBS blood collection systems. We described service user baseline characteristics and compared kit requests, kit and blood sample return rates, and the successful resulting rates for HIV and syphilis for MT and DBS. Pearson's χ2 and Fisher's exact test were used to determine statistical differences, and statistical formulae were applied to produce CIs for differences in proportions. RESULTS: 5670 STI postal kit requests from a Midlands region were reviewed from 6 September 2016-2 January 2019 (1515 MT and 4155 DBS). Baseline characteristics between the two groups were comparable (68.0% female, 74.0% white British and 87.5% heterosexual, median age 26 years). Successful processing rates for DBS were 94.6% and 54.4% for MT (p<0.001) with a percentage difference of 40.2% (95% CI 36.9% to 43.4%). The RRR for MT was 2.9 cf. 1.6 for DBS. False-positive results for MT samples were 5.2% (HIV) and 0.4% (syphilis), and those for DBS were 0.4% (HIV) and 0.0% (syphilis). CONCLUSIONS: This comparative analysis demonstrated the superior successful processing rates for postal DBS collection systems compared with MT. Reasons for this included insufficient volumes, high false-positive rates and degradation of blood quality in MT samples. A postal sampling service using DBS to screen for HIV, syphilis and other blood-borne viruses could be a viable alternative.


Subject(s)
Blood Specimen Collection/methods , Dried Blood Spot Testing/methods , HIV Infections/diagnosis , Syphilis/diagnosis , Adult , Blood Specimen Collection/instrumentation , Dried Blood Spot Testing/instrumentation , False Positive Reactions , Female , HIV Infections/blood , Humans , Male , Syphilis/blood , Syphilis Serodiagnosis , Young Adult
4.
Am J Hum Biol ; 32(5): e23394, 2020 09.
Article in English | MEDLINE | ID: covidwho-1005715

ABSTRACT

OBJECTIVES: Investigating factors that contribute to bone loss and accretion across populations in remote settings is challenging, particularly where diagnostic tools are scarce. To mitigate this challenge, we describe validation of a commercial ELISA assay to measure osteocalcin, a biomarker of bone formation, from dried blood spots (DBS). METHODS: We validated the Osteocalcin Human SimpleStep ELISA kit from Abcam (ab1951214) using 158 matched plasma and DBS samples. Passing-Bablok regression analysis assessed the relationships between plasma and DBS osteocalcin concentrations. Dilutional linearity and spike and recovery experiments determined if the DBS matrix interfered with osteocalcin measurement, and intra- and inter-assay coefficients of variation (CVs) were calculated. Limit of detection, analyte stability, and specific forms of osteocalcin measured by the kit were also investigated. RESULTS: Mean plasma osteocalcin value was 218.2 ng/mL (range 64.6-618.1 ng/mL). Linear relationships existed between plasma and DBS concentrations of osteocalcin, with no apparent bias in plasma vs DBS concentrations. There was no apparent interference of the DBS matrix with measurement of osteocalcin in DBS. Intra-assay CV for DBS was ~8%, while average inter-assay CV was 14.8%. Limit of detection was 0.34 ng/mL. Osteocalcin concentrations were stable in DBS stored at -28°C and room temperature, but not those stored at 37°C. This ELISA kit detects total osteocalcin. CONCLUSIONS: Osteocalcin, a bone formation biomarker, can be measured from DBS. Combined with a previously validated DBS assay for TRACP-5b, a bone resorption biomarker, these assays have the potential to help researchers disentangle the many factors contributing to bone strength.


Subject(s)
Dried Blood Spot Testing/methods , Enzyme-Linked Immunosorbent Assay/methods , Osteocalcin/blood , Osteogenesis/physiology , Adult , Aged , Biomarkers/blood , Dried Blood Spot Testing/instrumentation , Enzyme-Linked Immunosorbent Assay/instrumentation , Female , Humans , Male , Middle Aged , Oregon , Reproducibility of Results , Young Adult
5.
Sci Rep ; 10(1): 20188, 2020 11 19.
Article in English | MEDLINE | ID: covidwho-936146

ABSTRACT

Accurate surveillance of coronavirus disease 2019 (COVID-19) incidence requires large-scale testing of the population. Current testing methods require in-person collection of biospecimens by a healthcare worker, limiting access of individuals who do not have access to testing facilities while placing both patients and healthcare workers at risk of exposure to infection. We report the development and validation of a at-home finger-prick dried blood spot collection kit and an analysis method. We demonstrated 100% sensitivity and specificity using at-home collected specimens across the US. Such methods may facilitate the conduct of unbiased serosurveys within hard to reach populations and help reduce the sample collection burden of serological testing on both health care systems and individuals alike.


Subject(s)
COVID-19 Serological Testing/methods , Dried Blood Spot Testing/standards , Reagent Kits, Diagnostic/standards , Adult , Aged , Aged, 80 and over , COVID-19 Serological Testing/standards , Dried Blood Spot Testing/instrumentation , Female , Humans , Male , Middle Aged , Sensitivity and Specificity
6.
Drug Test Anal ; 13(1): 223-226, 2021 Jan.
Article in English | MEDLINE | ID: covidwho-910190

ABSTRACT

At the beginning of 2020, an outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reached pandemic dimensions. Throughout the event, diagnostic tests function as an essential tool for understanding, mitigating, and implement strategies to curb and reduce infections. Here, we present a novel method for the fully automated dried blood spot (DBS) sample handling and extraction for serological testing of human IgG antibodies against SARS-CoV-2 using a commercial enzyme-linked immunosorbent assay (ELISA) testing kit. This proof-of-principle pilot study successfully demonstrates the recovery of antibodies in their intact form from DBS using automated, direct sample elution within 100 µl of extraction buffer. The use of minimally invasive DBS sampling provides an alternative to existing analytical procedures such as sampling by venipuncture or nasal swabs. Due to the ease of DBS collection, no third party need be involved, making at-home sampling possible (e.g., during quarantine).


Subject(s)
Antibodies, Viral/analysis , COVID-19 Testing/methods , COVID-19/diagnosis , COVID-19/immunology , Dried Blood Spot Testing/methods , SARS-CoV-2/immunology , Automation , Dried Blood Spot Testing/instrumentation , Enzyme-Linked Immunosorbent Assay , Humans , Immunoglobulin G/analysis , Pandemics , Pilot Projects , Specimen Handling
SELECTION OF CITATIONS
SEARCH DETAIL